Keep unrelated pre-existing near-axis edges from disabling exact Resize handles, make tracked single-space fixtures visible to the invariants CLI, and add the three missing mutation gates plus real-plan coverage.
Issue: #290
User-Visible: no
Accepted the complete Linux artifact after visual review. Only the dark and light safe-resize handle views change intentionally; all other passing scenarios keep their prior bytes.
Issue: #289
User-Visible: no
Release: v1.67.0-beta.10
Baseline-Reviewed: https://github.com/Matysh/houseplan-card/actions/runs/32726613816
Accepted the complete Linux artifact after visual review. Only the dark and light isometric geometry views change intentionally; 106 passing scenarios keep their prior bytes.
Issue: #260
User-Visible: no
Release: v1.67.0-beta.10
Baseline-Reviewed: https://github.com/Matysh/houseplan-card/actions/runs/32725286757
Refresh the shared wall-key fixture contract and keep generated frontend bundles synchronized with the fingerprinted geometry fixtures.
Issue: #260
User-Visible: no
The continuity gate cannot see the defect from the owner's 66.json: masonry is
continuous there and the record agrees with what is painted. The record itself
is wrong — a partial resize left 43 steps of a former shared boundary as an
exterior wall while it kept the 20 cm of that boundary, next to 30 cm exterior
neighbours. Thickness followed the key, not the role of the edge.
A width check would not have caught it, and I built one before throwing it away.
It compares the painted body against the record, and here the two agree. On real
plans it also fires where masonry is legitimately wider — columns, junction
influence, abutting parallel walls: 76 to 82 steps measured against 4 expected,
every case legal. A gate that needs explaining half the time is noise.
The defect is expressible in a single state instead: one record whose span is
partly shared and partly exterior. Nobody sets that on purpose. Roles come from
the polygons — a stretch is shared when another room's edge covers it — so the
check needs neither a build nor product code.
Two traps found by measurement, both of which produced false positives. Count
distinct rooms rather than edges: in a corner one room owns two edges, and
counting edges called every exterior corner a shared boundary — 12 and 14 false
positives. And do not sample the endpoints: an endpoint is a node, where a wall
legitimately touches two rooms, and including them reported 95 per cent exterior
on every wall abutting a shared one.
Mutation coverage, stated honestly: the endpoint mutant is killed by the
real-plan test. The rooms-versus-edges mutant survived — once endpoints are
excluded, counting edges gives the same answer on real plans, so that choice is
not load-bearing. I removed the mutant rather than ship a surviving one, and said
so in the code.
Issue: #287
User-Visible: no
The second floor covers one class: the multi-wall corridor eating a neighbouring
wall. The first floor brings what neither it nor any synthetic fixture has —
three virtual spans, two wall columns, two solid edges with no thickness record
at all, and 127 noisy coordinates.
The two plans pin opposite states, which is worth more than two plans with the
same defect: one records a known debt of 181 steps, the other records cleanliness
at zero. A regression is caught in both directions.
A declared virtual span is a declared break, not a defect, so the rule from #285
would have reddened on the first floor's own contract. Samples lying on
open_spans are now excluded: 830 of 6800 on that plan, and the remaining gap
count is zero.
The two zero-thickness solid edges are two grid steps long and covered by the
bodies of their neighbours, so the browser sees no break. Their count is
therefore pinned in the model test rather than the smoke — if it grows, or if the
neighbours stop covering them, that shows up before it becomes a hole.
Both fixtures must stay noisy: the project's synthetic models carry exactly zero
noise, which is why #258 and #248 are not reproducible on them. A profile check
asserts at least a hundred noisy coordinates each, so a future write barrier run
over the fixtures cannot quietly rob them of their purpose.
Privacy: names, ids, markers, device bindings and layout are gone; geometry
stays, coordinates unchanged, because they are the point.
Issue: #286
User-Visible: no